PCWORX

2813 products

  • Last stock! Schneider Acti9 IEC 2P 16A C DIN-Rail Type Miniature Circuit Breaker 230/400V (A9F74216)

    Schneider Acti9 IEC 2P 16A C DIN-Rail Type Miniature Circuit Breaker 230/400V (A9F74216)

    5 in stock

    Specifications  Model:  Acti9 iC60N Catalog Number:  A9F74216 Poles:  2P Rated Current:  16A Tripping Characteristic:  Type C Nominal AC Voltage:  500V AC Rated AC Voltage (Ue):  Up to 440 VAC Performance & Electrical Features  Interrupting Capacity:  10 kA (IEC 60947-2) Breaking Capacity (IEC 60898-1):  6kA at 400V AC Electrical Life:  10,000 cycles Mechanical Life:  20,000 cycles VisiTrip™:  Indicates the faulty circuit for quick diagnosis VisiSafe™:  Ensures the downstream circuit is always safe Communication Ready:  With Acti9 Smartlink Installation & Environmental  Mounting:  DIN-rail mount Dimensions:  36mm (W) x 85mm (H) x 78.5mm (D) Operating Temperature:  -35°C to 70°C Storage Temperature:  -40°C to 85°C Degree of Protection (IP):  IP20 Standards Compliance  Industry Standards:  Fully compliant with IEC/EN 60898-1 and IEC/EN 60947-2

    5 in stock

    ₱914.76

  • Schneider Acti9 IEC 2P 25A C DIN-Rail Type Miniature Circuit Breaker 440V 10kAIC (A9F74225)

    Schneider Acti9 IEC 2P 25A C DIN-Rail Type Miniature Circuit Breaker 440V 10kAIC (A9F74225)

    10 in stock

    Category Parameter Specification Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 Rated current [In] 25 A Network type AC / DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6 kA Icn at 400 V AC 50/60 Hz (EN/IEC 60898-1) 36 kA Icu at 12…133 V AC 50/60 Hz (EN/IEC 60947-2) 20 kA Icu at 220…240 V AC 50/60 Hz (EN/IEC 60947-2) 10 kA Icu at 380…415 V AC 50/60 Hz (EN/IEC 60947-2) 6 kA Icu at 440 V AC 50/60 Hz (EN/IEC 60947-2) 10 kA Icu at ≤125 V DC (EN/IEC 60947-2) Utilisation category Category A (EN / IEC 60947-2) Suitability for isolation Yes (EN / IEC 60898-1 & 60947-2) Standards IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 × In ±20 % Rated service breaking capacity [Ics] 15 kA (75% Icu) at 220…240 V AC (EN/IEC 60947-2) 7.5 kA (75% Icu) at 380…415 V AC (EN/IEC 60947-2) 4.5 kA (75% Icu) at 440 V AC (EN/IEC 60947-2) 27 kA (75% Icu) at 12…133 V AC (EN/IEC 60947-2) 6 kA (100% Icn) at 400 V AC (EN/IEC 60898-1) 10 kA (100%) at 72…125 V DC (EN/IEC 60947-2) Limitation class Class 3 (EN / IEC 60898-1) Rated insulation voltage [Ui] 500 V AC 50/60 Hz (EN / IEC 60947-2) Rated impulse withstand voltage [Uimp] 6 kV (EN / IEC 60947-2) Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar compatibility Top or bottom: Yes Number of 9 mm pitches 4 Dimensions & Physical Height 85 mm Width 36 mm Depth 78.5 mm Net weight 0.25 kg Colour White Mechanical durability 20,000 cycles Electrical durability 10,000 cycles Connections Terminal type Single terminal (top or bottom) Rigid conductor size 1…25 mm² Flexible conductor size 1…16 mm² Wire stripping length 14 mm Tightening torque 2 N·m Earth-leakage protection Separate block Environment IP degree of protection IP20 (IEC / EN 60529) Pollution degree 3 (IEC / EN 60947-2) Overvoltage category IV Tropicalisation 2 (IEC 60068-1) Relative humidity 95 % at 55 °C Operating altitude 0…2000 m Operating temperature -35…70 °C Storage temperature -40…85 °C

    10 in stock

    ₱834.96

  • Last stock! Schneider Acti9 IEC 2P 40A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74240)

    Schneider Acti9 IEC 2P 40A C DIN-Rail Type Miniature Circuit Breaker 230/400V 10kAIC (A9F74240)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 40 A Network type DC AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 4 Height 85 mm Width 36 mm Depth 78.5 mm Net weight 0.25 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Earth-leakage protection Separate block Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.500 cm Package 1 Width 3.500 cm Package 1 Length 9.500 cm Package 1 Weight 239.000 g Unit Type of Package 2 BB1 Number of Units in Package 2 6 Package 2 Height 8.000 cm Package 2 Width 9.600 cm Package 2 Length 22.500 cm Package 2 Weight 1.493 kg Unit Type of Package 3 S03 Number of Units in Package 3 66 Package 3 Height 30.000 cm Package 3 Width 30.000 cm Package 3 Length 40.000 cm Package 3 Weight 17.009 kg

    5 in stock

    ₱834.96

  • Last stock! Schneider Acti9 IEC, 1-Pole 20A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74120)

    Schneider Acti9 IEC, 1-Pole 20A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74120)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 20 A Network type AC DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 2 Height 85 mm Width 18 mm Depth 78.5 mm Net weight 0.215 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Without Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 1.800 cm Package 1 Width 7.300 cm Package 1 Length 9.500 cm Package 1 Weight 114.000 g Unit Type of Package 2 BB1 Number of Units in Package 2 12 Package 2 Height 8.000 cm Package 2 Width 10.000 cm Package 2 Length 22.500 cm Package 2 Weight 1.424 kg Unit Type of Package 3 S03 Number of Units in Package 3 132 Package 3 Height 30.000 cm Package 3 Width 30.000 cm Package 3 Length 40.000 cm Package 3 Weight 16.160 kg

    5 in stock

    ₱472.92

  • Last stock! Schneider Acti9 IEC, 1-Pole 32A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74132)

    Schneider Acti9 IEC, 1-Pole 32A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74132)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 32 A Network type AC DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60947-2 IEC 60947-2 EN 60898-1 IEC 60898-1 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 2 Height 85 mm Width 18 mm Depth 78.5 mm Net weight 0.215 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Earth-leakage protection Without Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.000 cm Package 1 Width 7.500 cm Package 1 Length 9.500 cm Package 1 Weight 120.500 g Unit Type of Package 2 BB1 Number of Units in Package 2 12 Package 2 Height 8.000 cm Package 2 Width 10.000 cm Package 2 Length 22.500 cm Package 2 Weight 1.500 kg Unit Type of Package 3 S03 Number of Units in Package 3 132 Package 3 Height 30.000 cm Package 3 Width 30.000 cm Package 3 Length 40.000 cm Package 3 Weight 16.876 kg

    5 in stock

    ₱495.60

  • Last stock! Schneider Acti9 IEC, 1-Pole 40A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74140)

    Schneider Acti9 IEC, 1-Pole 40A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74140)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 1P Number of protected poles 1 [In] rated current 40 A Network type AC DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 2 Height 85 mm Width 18 mm Depth 78.5 mm Net weight 0.215 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Earth-leakage protection Without Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.5 cm Package 1 Width 1.8 cm Package 1 Length 9.5 cm Package 1 Weight 119.0 g Unit Type of Package 2 BB1 Number of Units in Package 2 12 Package 2 Height 7.8 cm Package 2 Width 9.8 cm Package 2 Length 22.2 cm Package 2 Weight 1.497 kg Unit Type of Package 3 S03 Number of Units in Package 3 132 Package 3 Height 30.0 cm Package 3 Width 30.0 cm Package 3 Length 40.0 cm Package 3 Weight 16.976 kg

    5 in stock

    ₱504.00

  • Schneider Acti9 IEC, 2-Pole 63A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74263)

    Schneider Acti9 IEC, 2-Pole 63A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74263)

    Out of stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 63 A Network type DC AC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards IEC 60898-1 EN 60947-2 EN 60898-1 IEC 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC Limitation class 3 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 4 Height 85 mm Width 36 mm Depth 78.5 mm Net weight 0.25 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Earth-leakage protection Separate block Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.500 cm Package 1 Width 3.600 cm Package 1 Length 9.500 cm Package 1 Weight 252.000 g Unit Type of Package 2 BB1 Number of Units in Package 2 6 Package 2 Height 8.000 cm Package 2 Width 10.000 cm Package 2 Length 22.500 cm Package 2 Weight 1.572 kg Unit Type of Package 3 S03 Number of Units in Package 3 66 Package 3 Height 30.000 cm Package 3 Width 30.000 cm Package 3 Length 40.000 cm Package 3 Weight 17.900 kg

    Out of stock

    ₱1,276.80

  • Last stock! Schneider Acti9 IEC, 2-Pole 6A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74206)

    Schneider Acti9 IEC, 2-Pole 6A DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74206)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 6:00 AM Network type AC DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 4 Height 85 mm Width 36 mm Depth 78.5 mm Net weight 0.25 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Separate block Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.500 cm Package 1 Width 3.700 cm Package 1 Length 9.500 cm Package 1 Weight 213.000 g Unit Type of Package 2 BB1 Number of Units in Package 2 6 Package 2 Height 8.500 cm Package 2 Width 10.000 cm Package 2 Length 22.500 cm Package 2 Weight 1.346 kg Unit Type of Package 3 S03 Number of Units in Package 3 66 Package 3 Height 30.000 cm Package 3 Width 30.000 cm Package 3 Length 40.000 cm Package 3 Weight 15.293 kg

    5 in stock

    ₱787.92

  • Last stock! Schneider Acti9 IEC, 50A 2-Pole DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74250)

    Schneider Acti9 IEC, 50A 2-Pole DIN-Rail Type Circuit Breaker 230/400V 10 KAIC (A9F74250)

    5 in stock

    Specifications Main Device application Distribution Range Acti9 Product name Acti9 iC60 Product or component type Miniature circuit-breaker Device short name IC60N Poles description 2P Number of protected poles 2 [In] rated current 50 A Network type AC DC Trip unit technology Thermal-magnetic Curve code C Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 Standards EN 60898-1 IEC 60898-1 IEC 60947-2 EN 60947-2 Complementary Network frequency 50/60 Hz Magnetic tripping limit 8 x In +/- 20 % [Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC Limitation class 3 [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 Contact position indicator Yes Control type Toggle Local signalling Trip indicator Mounting mode Fixed Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES 9 mm pitches 4 Height 85 mm Width 36 mm Depth 78.5 mm Net weight 0.25 kg Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible Wire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Earth-leakage protection Separate block Environment IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529 Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 Overvoltage category IV Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Operating altitude 0...2000 m Ambient air temperature for operation -35…70 °C Ambient air temperature for storage -40…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 3.5 cm Package 1 Width 7.0 cm Package 1 Length 9.5 cm Package 1 Weight 253.0 g Unit Type of Package 2 BB1 Number of Units in Package 2 6 Package 2 Height 8.0 cm Package 2 Width 9.7 cm Package 2 Length 22.5 cm Package 2 Weight 1.581 kg Unit Type of Package 3 S03 Number of Units in Package 3 66 Package 3 Height 30.0 cm Package 3 Width 30.0 cm Package 3 Length 40.0 cm Package 3 Weight 17.906 kg

    5 in stock

    ₱1,050.84

  • Last stock! Schneider AvatarOn A 1 gang Grid Plate - BLACK M3T01-BK

    Schneider AvatarOn A 1 gang Grid Plate - BLACK M3T01-BK

    5 in stock

    Specifications Main Range of product AvatarOn A Product or component type Grid plate Number of gangs 1 gang Colour tint Black Colour tint Black Complementary Material PC: grid plate PC: side panels Device mounting Flush Width 120 mm Height 70 mm Depth 22.7 mm Environment Ambient air temperature for operation -5…45 °C Relative humidity 0…95 % Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.37 cm Package 1 Width 7 cm Package 1 Length 12 cm Package 1 Weight 76 g Unit Type of Package 2 BB1 Number of Units in Package 2 10 Package 2 Height 9.1 cm Package 2 Width 13 cm Package 2 Length 25.5 cm Package 2 Weight 0.84 kg Unit Type of Package 3 S03 Number of Units in Package 3 80 Package 3 Height 30 cm Package 3 Width 30 cm Package 3 Length 40 cm Package 3 Weight 7.37 kg

    5 in stock

    ₱63.60

  • Last stock! Schneider AvatarOn A 1 gang Grid Plate - GREY M3T01-GY

    Schneider AvatarOn A 1 gang Grid Plate - GREY M3T01-GY

    5 in stock

    Specifications Main Range of product AvatarOn A Product or component type Grid plate Number of gangs 1 gang Colour tint Grey Colour tint Grey Complementary Material PC: grid plate PC: side panels Device mounting Flush Width 120 mm Height 70 mm Depth 22.7 mm Environment Ambient air temperature for operation -5…45 °C Relative humidity 0…95 % Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.37 cm Package 1 Width 7 cm Package 1 Length 12 cm Package 1 Weight 76 g Unit Type of Package 2 BB1 Number of Units in Package 2 10 Package 2 Height 9.1 cm Package 2 Width 13 cm Package 2 Length 25.5 cm Package 2 Weight 0.84 kg Unit Type of Package 3 S03 Number of Units in Package 3 80 Package 3 Height 30 cm Package 3 Width 30 cm Package 3 Length 40 cm Package 3 Weight 7.37 kg

    5 in stock

    ₱63.60

  • Schneider AvatarOn A 1 gang Grid Plate - WHITE M3T01-WE

    Schneider AvatarOn A 1 gang Grid Plate - WHITE M3T01-WE

    10 in stock

    Category Parameter Specification Main Range of product AvatarOn A Product or component type Grid plate Number of gangs 1 gang Colour tint White Complementary Material PC (grid plate) PC (side panels) Device mounting Flush Dimensions Width 120 mm Height 70 mm Depth 22.7 mm Environment Ambient air temperature for operation -5…45 °C Relative humidity 0…95 % Packing Units Unit type of Package 1 PCE Number of units in Package 1 1 Package 1 height 2.4 cm Package 1 width 7 cm Package 1 length 12 cm Package 1 weight 77 g

    10 in stock

    ₱48.00

© 2025 PCWORX, Powered by Shopify

      Login

      Forgot your password?

      Don't have an account yet?
      Create account