Specifications
Model:
Acti9 iC60N
Catalog Number:
A9F74216
Poles:
2P
Rated Current:
16A
Tripping Characteristic:
Type C
Nominal AC Voltage:
500V AC
Rated AC Voltage (Ue):
Up to 440 VAC
Performance & Electrical Features
Interrupting Capacity:
10 kA (IEC 60947-2)
Breaking Capacity (IEC 60898-1):
6kA at 400V AC
Electrical Life:
10,000 cycles
Mechanical Life:
20,000 cycles
VisiTrip™:
Indicates the faulty circuit for quick diagnosis
VisiSafe™:
Ensures the downstream circuit is always safe
Communication Ready:
With Acti9 Smartlink
Installation & Environmental
Mounting:
DIN-rail mount
Dimensions:
36mm (W) x 85mm (H) x 78.5mm (D)
Operating Temperature:
-35°C to 70°C
Storage Temperature:
-40°C to 85°C
Degree of Protection (IP):
IP20
Standards Compliance
Industry Standards:
Fully compliant with IEC/EN 60898-1 and IEC/EN 60947-2
Category
Parameter
Specification
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
2P
Number of protected poles
2
Rated current [In]
25 A
Network type
AC / DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6 kA Icn at 400 V AC 50/60 Hz (EN/IEC 60898-1)
36 kA Icu at 12…133 V AC 50/60 Hz (EN/IEC 60947-2)
20 kA Icu at 220…240 V AC 50/60 Hz (EN/IEC 60947-2)
10 kA Icu at 380…415 V AC 50/60 Hz (EN/IEC 60947-2)
6 kA Icu at 440 V AC 50/60 Hz (EN/IEC 60947-2)
10 kA Icu at ≤125 V DC (EN/IEC 60947-2)
Utilisation category
Category A (EN / IEC 60947-2)
Suitability for isolation
Yes (EN / IEC 60898-1 & 60947-2)
Standards
IEC 60898-1, IEC 60947-2, EN 60898-1, EN 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 × In ±20 %
Rated service breaking capacity [Ics]
15 kA (75% Icu) at 220…240 V AC (EN/IEC 60947-2)
7.5 kA (75% Icu) at 380…415 V AC (EN/IEC 60947-2)
4.5 kA (75% Icu) at 440 V AC (EN/IEC 60947-2)
27 kA (75% Icu) at 12…133 V AC (EN/IEC 60947-2)
6 kA (100% Icn) at 400 V AC (EN/IEC 60898-1)
10 kA (100%) at 72…125 V DC (EN/IEC 60947-2)
Limitation class
Class 3 (EN / IEC 60898-1)
Rated insulation voltage [Ui]
500 V AC 50/60 Hz (EN / IEC 60947-2)
Rated impulse withstand voltage [Uimp]
6 kV (EN / IEC 60947-2)
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar compatibility
Top or bottom: Yes
Number of 9 mm pitches
4
Dimensions & Physical
Height
85 mm
Width
36 mm
Depth
78.5 mm
Net weight
0.25 kg
Colour
White
Mechanical durability
20,000 cycles
Electrical durability
10,000 cycles
Connections
Terminal type
Single terminal (top or bottom)
Rigid conductor size
1…25 mm²
Flexible conductor size
1…16 mm²
Wire stripping length
14 mm
Tightening torque
2 N·m
Earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 (IEC / EN 60529)
Pollution degree
3 (IEC / EN 60947-2)
Overvoltage category
IV
Tropicalisation
2 (IEC 60068-1)
Relative humidity
95 % at 55 °C
Operating altitude
0…2000 m
Operating temperature
-35…70 °C
Storage temperature
-40…85 °C
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
2P
Number of protected poles
2
[In] rated current
40 A
Network type
DC
AC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
78.5 mm
Net weight
0.25 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
3.5 N.m top or bottom
Earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.500 cm
Package 1 Width
3.500 cm
Package 1 Length
9.500 cm
Package 1 Weight
239.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.000 cm
Package 2 Width
9.600 cm
Package 2 Length
22.500 cm
Package 2 Weight
1.493 kg
Unit Type of Package 3
S03
Number of Units in Package 3
66
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
17.009 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
1P
Number of protected poles
1
[In] rated current
20 A
Network type
AC
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
2
Height
85 mm
Width
18 mm
Depth
78.5 mm
Net weight
0.215 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Without
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
1.800 cm
Package 1 Width
7.300 cm
Package 1 Length
9.500 cm
Package 1 Weight
114.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
8.000 cm
Package 2 Width
10.000 cm
Package 2 Length
22.500 cm
Package 2 Weight
1.424 kg
Unit Type of Package 3
S03
Number of Units in Package 3
132
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
16.160 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
1P
Number of protected poles
1
[In] rated current
32 A
Network type
AC
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60947-2
IEC 60947-2
EN 60898-1
IEC 60898-1
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
2
Height
85 mm
Width
18 mm
Depth
78.5 mm
Net weight
0.215 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
3.5 N.m top or bottom
Earth-leakage protection
Without
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.000 cm
Package 1 Width
7.500 cm
Package 1 Length
9.500 cm
Package 1 Weight
120.500 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
8.000 cm
Package 2 Width
10.000 cm
Package 2 Length
22.500 cm
Package 2 Weight
1.500 kg
Unit Type of Package 3
S03
Number of Units in Package 3
132
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
16.876 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
1P
Number of protected poles
1
[In] rated current
40 A
Network type
AC
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60898-1
IEC 60947-2
IEC 60898-1
EN 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
2
Height
85 mm
Width
18 mm
Depth
78.5 mm
Net weight
0.215 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
3.5 N.m top or bottom
Earth-leakage protection
Without
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.5 cm
Package 1 Width
1.8 cm
Package 1 Length
9.5 cm
Package 1 Weight
119.0 g
Unit Type of Package 2
BB1
Number of Units in Package 2
12
Package 2 Height
7.8 cm
Package 2 Width
9.8 cm
Package 2 Length
22.2 cm
Package 2 Weight
1.497 kg
Unit Type of Package 3
S03
Number of Units in Package 3
132
Package 3 Height
30.0 cm
Package 3 Width
30.0 cm
Package 3 Length
40.0 cm
Package 3 Weight
16.976 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
2P
Number of protected poles
2
[In] rated current
63 A
Network type
DC
AC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
IEC 60898-1
EN 60947-2
EN 60898-1
IEC 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class
3
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
78.5 mm
Net weight
0.25 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
3.5 N.m top or bottom
Earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.500 cm
Package 1 Width
3.600 cm
Package 1 Length
9.500 cm
Package 1 Weight
252.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.000 cm
Package 2 Width
10.000 cm
Package 2 Length
22.500 cm
Package 2 Weight
1.572 kg
Unit Type of Package 3
S03
Number of Units in Package 3
66
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
17.900 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
2P
Number of protected poles
2
[In] rated current
6:00 AM
Network type
AC
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60898-1
IEC 60898-1
EN 60947-2
IEC 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class
3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
78.5 mm
Net weight
0.25 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
2 N.m top or bottom
Earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.500 cm
Package 1 Width
3.700 cm
Package 1 Length
9.500 cm
Package 1 Weight
213.000 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.500 cm
Package 2 Width
10.000 cm
Package 2 Length
22.500 cm
Package 2 Weight
1.346 kg
Unit Type of Package 3
S03
Number of Units in Package 3
66
Package 3 Height
30.000 cm
Package 3 Width
30.000 cm
Package 3 Length
40.000 cm
Package 3 Weight
15.293 kg
Specifications
Main
Device application
Distribution
Range
Acti9
Product name
Acti9 iC60
Product or component type
Miniature circuit-breaker
Device short name
IC60N
Poles description
2P
Number of protected poles
2
[In] rated current
50 A
Network type
AC
DC
Trip unit technology
Thermal-magnetic
Curve code
C
Breaking capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category
Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation
Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards
EN 60898-1
IEC 60898-1
IEC 60947-2
EN 60947-2
Complementary
Network frequency
50/60 Hz
Magnetic tripping limit
8 x In +/- 20 %
[Ics] rated service breaking capacity
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class
3
[Ui] rated insulation voltage
500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator
Yes
Control type
Toggle
Local signalling
Trip indicator
Mounting mode
Fixed
Mounting support
DIN rail
Comb busbar and distribution block compatibility
Top or bottom: YES
9 mm pitches
4
Height
85 mm
Width
36 mm
Depth
78.5 mm
Net weight
0.25 kg
Colour
White
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Connections - terminals
Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length
14 mm for top or bottom connection
Tightening torque
3.5 N.m top or bottom
Earth-leakage protection
Separate block
Environment
IP degree of protection
IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree
3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category
IV
Tropicalisation
2 conforming to IEC 60068-1
Relative humidity
95 % at 55 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-35…70 °C
Ambient air temperature for storage
-40…85 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.5 cm
Package 1 Width
7.0 cm
Package 1 Length
9.5 cm
Package 1 Weight
253.0 g
Unit Type of Package 2
BB1
Number of Units in Package 2
6
Package 2 Height
8.0 cm
Package 2 Width
9.7 cm
Package 2 Length
22.5 cm
Package 2 Weight
1.581 kg
Unit Type of Package 3
S03
Number of Units in Package 3
66
Package 3 Height
30.0 cm
Package 3 Width
30.0 cm
Package 3 Length
40.0 cm
Package 3 Weight
17.906 kg
Specifications
Main
Range of product
AvatarOn A
Product or component type
Grid plate
Number of gangs
1 gang
Colour tint
Black
Colour tint
Black
Complementary
Material
PC: grid plate
PC: side panels
Device mounting
Flush
Width
120 mm
Height
70 mm
Depth
22.7 mm
Environment
Ambient air temperature for operation
-5…45 °C
Relative humidity
0…95 %
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.37 cm
Package 1 Width
7 cm
Package 1 Length
12 cm
Package 1 Weight
76 g
Unit Type of Package 2
BB1
Number of Units in Package 2
10
Package 2 Height
9.1 cm
Package 2 Width
13 cm
Package 2 Length
25.5 cm
Package 2 Weight
0.84 kg
Unit Type of Package 3
S03
Number of Units in Package 3
80
Package 3 Height
30 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
7.37 kg
Specifications
Main
Range of product
AvatarOn A
Product or component type
Grid plate
Number of gangs
1 gang
Colour tint
Grey
Colour tint
Grey
Complementary
Material
PC: grid plate
PC: side panels
Device mounting
Flush
Width
120 mm
Height
70 mm
Depth
22.7 mm
Environment
Ambient air temperature for operation
-5…45 °C
Relative humidity
0…95 %
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.37 cm
Package 1 Width
7 cm
Package 1 Length
12 cm
Package 1 Weight
76 g
Unit Type of Package 2
BB1
Number of Units in Package 2
10
Package 2 Height
9.1 cm
Package 2 Width
13 cm
Package 2 Length
25.5 cm
Package 2 Weight
0.84 kg
Unit Type of Package 3
S03
Number of Units in Package 3
80
Package 3 Height
30 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
7.37 kg
Category
Parameter
Specification
Main
Range of product
AvatarOn A
Product or component type
Grid plate
Number of gangs
1 gang
Colour tint
White
Complementary
Material
PC (grid plate)
PC (side panels)
Device mounting
Flush
Dimensions
Width
120 mm
Height
70 mm
Depth
22.7 mm
Environment
Ambient air temperature for operation
-5…45 °C
Relative humidity
0…95 %
Packing Units
Unit type of Package 1
PCE
Number of units in Package 1
1
Package 1 height
2.4 cm
Package 1 width
7 cm
Package 1 length
12 cm
Package 1 weight
77 g